Appendix B. Server Serial Connector Pinouts

This appendix contains these sections:

Origin2000 and Onyx2 Serial Pinout

Each Origin2000 or Onyx 2 system comes with two standard 9-pin serial ports. These ports can support either RS-232 or RS-422 interface devices. Figure B-1 shows the location and pinouts for a serial port. Optional additional serial ports are also available.

Figure B-1. Serial Port Location and Pinouts


This connector departs from traditional Silicon Graphics usage:

  • Pin 2 (not pin 3) is Receive Data (RD)

  • Pin 3 (not pin 2) is Transmit Data (TD)

  • Pin 5 (not pin 7) is signal ground

  • gender is female (not male)

Table B-1 shows the correspondence between this connector and the SP connector.

Table B-1. Origin2000/Onyx2 and SP Serial Connectors

Origin2000/Onyx2 Serial Connector Pin

SP Connector Pin

2

3

3

2

5

7

The RS-232 standard recommends the use of cables no longer than 50 feet (15.2 meters). (This standard should also be applied for an RS-422 connector.) Longer runs increases the possibility of line noise which can affect data transmission and cause errors. For cable runs longer than 50 feet (15.2 meters), use an appropriate extender device.

Origin200 Serial Pinouts

Figure B-2 shows pin numbering for the Origin200 serial port.

Figure B-2. Origin200 Serial Port Pinout Assignments


Table B-2 shows the connector pin assignments for the serial ports in RS-232 mode.

Table B-2. Origin200 Serial Port Pin Assignments, RS-232 Mode

Pin

Assignment

1

Data Carrier Detect (DCD)

2

Receive Data (RXD)

3

Transmit Data (TXD)

4

Data Terminal Ready (DTR)

5

Ground (GND)

6

Data Set Ready (DSR)

7

Request To Send (RTS)

8

Clear To Send (CTS)

9

(Not Connected)


OCTANE Serial Pinouts

The OCTANE workstation serial ports can operate in RS-232 electrical levels with a standard PC pinout; the range of supported baud rates is 300 baud to 460K baud. Figure B-3 shows pin numbering.

Figure B-3. OCTANE Serial Port


Table B-3 shows cable pinout assignments for the serial ports.

Table B-3. OCTANE PC-Compatible Serial Port Pinout

Pin

Assignment

Description

1

DCD

Data Carrier Detect

2

RD

Receive Data

3

TD

Transmit Data

4

DTR

Data Terminal Ready

5

SG

Signal Ground

6

DSR

Data Set Ready

7

RTS

Request to Send

8

CTS

Clear to Send

9

RI

Ring Indicator

For information on operating the serial ports with Macintosh style electrical levels and a Macintosh-compatible pinout or with ANSI/SMPTE 207M electrical levels and pinout, or for information on connecting a dumb terminal, see the OCTANE Workstation Owner's Guide.